Find Thermocouple Strip, Type K Sheet, Compensating Strip on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Inquiry Basket (0)
Home > Products > Thermocouple Alloy > Manufacturer K Type Thermocouple Compensating Wire

Manufacturer K Type Thermocouple Compensating Wire

Basic Info

Model No.:  type K

Product Description

Model NO.: type K Product: Thermocouple Compensating Wire Delivery Time: 5-10days of Certificate: ISO 9001 Treatment: Hydrogen Annealing Process Standard: IEC-584 Sensing Type: Thermocouple Output Signal Type: Digital Type Measuring Medium: Temperature Customized: Customized Specification: IEC-584 HS Code: 750522 Certification: RoHS Condition: Soft Bright MOQ: 1kg of Application: Measurement Tolerance: Class 1 Standard Installation Type: Wall-Mounted Type Contact: Contact Production Process: Ceramics IP Rating: IP20 Trademark: WISDOM Origin: Shanghai, China Manufacturer K type thermocouple compensating wire We are your reliable alloy cinsultant 
  1.WHY CHOOSE WISDOM NICR HIGH QUALITY THERMOCOUPLE ALLOYS?   All our raw material is made from prime material, not recycle material. We have more than 25 years experience in manufacturing thermocouple alloys.   In the market, not all the Thermocouple alloys are with standard chemical composition and stable EMF. Professional and reliable is the soul of our business.   2.DESCRIPTION OF THERMOCOUPLE ALLOYS:   A thermocouple is a temperature measuring device consisting of two conductors of dissimilar metals or alloys that are connected only at the ends. When the ends are at different temperatures a small voltage is produced in the wire that can be related directly to the temperature difference between the ends. If the temperature at one end is known, the temperature at the other end can be determined. 

Thermocouple wire or extension grade wire is recommended to be used to connect thermocouples to the sensing or control instrumentation. The conditions of measurement determine the type of Thermocouple Wire and insulation to be used. Temperature range, environment, insulation requirements, response, and service life should be considered.  Thermocouple temperature range and tolerance  
Type Standard Operating temperature range (°C) Tolerance(°C)
Long term Short term Grade Temperature range Tolerance
Type K GB/T2614 K 1200 1300 I -40~1100 ±1.5°C/±0.4%t
II -40~1300 ±2.5°C/±0.75%t
Type N GB/T17615 N 1200 1300 I -40~1100 ±1.5°C/±0.4%t
II -40~1300 ±2.5°C/±0.75%t
Type E GB/T4993 E 750 900 I -40~800 ±1.5°C/±0.4%t
II -40~900 ±2.5°C/±0.75%t
Type J GB/T4994 J 600 750 I 0~750 ±1.5°C/±0.4%t
II ±2.5°C/±0.75%t
Type T GB/T2903 T 300 350 I -40~350 ±0.5°C/±0.4%t
II ±1°C/±0.75%t
III -200~40 ±1°C/±1.5%t
 
  3.WISDOM THERMOCOUPLE ALLOYS CHARACTERISTICS:   1)Manufactured according to international quality. System (ISO9001)  IEC584-1 IEC584-2 standard   2)Stable EMF and long-life span   3)Mill test certificate will be provided after production   4)Size range  wire:.0.05-10mm  ribbons: 0.05-0.2*2-6mm  strips: 0.05-5*5-250mm   5)Good packing methods to keep goods no damage during delivery   6)Customized lable, packing, OEM service   7)24 hours after-sale service   4.MAIN CHARACTERISTICS OF WISDOM THERMOCOUPLE ALLOYS   TYPE J (Iron vs Constantan) is used in vacuum, oxidizing, inert or reducing atmospheres. Iron element oxidizes rapidly at temperatures exceeding 538'C, and therefore heavier gauge wire is recommended for longer life at these temperatures. 

TYPE K (CHROMEL vs ALUMEL ) is used in oxidizing, inert or dry reducing atmospheres. Exposure to vacuum limited to short time periods. Must be protected from sulfurous and marginally oxidizing atmospheres. Reliable and accurate at high temperatures. 

TYPE T (Copper vs Constantan) is used or service in oxidizing, inert or reducing atmospheres or in vacuum. It is highly resistant to corrosion from atmospheric moisture and condensation and exhibits high stability at low temperatures. It is the only type with limits of error guaranteed for cryogenic temperatures.

TYPE E (CHROMEL vs Constantan) may be used in oxidizing, inert or dry reducing atmospheres, or for short periods of time under vacuum. Must be protected from sulfurous and marginally oxidizingatmospheres. Produces the highest EMF per degree o any standardized thermocouple.   Type N thermocouple (Ni Cr Si-Ni Si Mg)  is the latest base metal thermocouple, developed to improve the drawbacks that type K thermocouple has. The main chemical composition of positive leg Nicrosil(NP) is Ni: Cr: Si≈84.4: 14.2: 1.4; negative leg Nisil (NN) is Ni: Si: Mg≈95.5: 4.4: 0.1. Type N thermocouple also be used in the similar atmospheres that type K works, and the operating temperature range is -200~1300 °C.

Contact us if you need more details on Thermocouple Wire. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Thermocouple Compensating Wire、K Type Thermocouple. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Thermocouple Alloy